Sebaey Mahgoub1,2*

1Research and Development, Unipharma, El-Obour City, Egypt 2Food Analysis Laboratory, Ministry of Health, Zagazig, Egypt

Corresponding Author:

Sebaey Mahgoub, Research and Development, Unipharma, El-Obour City, and Food Analysis Laboratory, Ministry of Health, Zagazig, Egypt, Email: dr_semahgoub@yahoo.com

Keywords

RP-HPLC; Calcium gluconate; Calcium phospholactate; Method validation

Abstract

A simple, precise and accurate reversed phase high performance liquid chromatography (RP-HPLC) method was developed and validated for identification and simultaneous estimation of calcium gluconate and calcium phospholactate in a tablet dosage form. Detection and quantitation were performed by a Shimadzu Nexera LC-30AD system. Separation of the two analytes was achieved within 5 minutes by using Inertsil C18-3 column (4.6 mm x 150 mm, 5µm) and isocratic elution of aqueous solution of 1% (v/v) phosphoric acid and methanol by (90: 10, v/v) ratio at a flow rate of 1.0 mL/min. Detection was monitored at 210 nm. The linearity for calcium gluconate was in the range of 1.92-2.88mg/ mL with correlation coefficient of 0.9982 and linearity for calcium phospholactate was in the range of 2-3mg/ mL, with correlation coefficient of 0.9981, respectively. Stability indicating capability was established by forced degradation experiments. The proposed method was validated for linearity, repeatability, accuracy, specificity, robustness, Limit of Detection (LOD) and Limit of Quantification (LOQ). The developed method was successfully applied in analysis of a tablet formula.

Citation

Mahgoub S. Validated RP-HPLC Method for Identification and Simultaneous Quantitation of Calcium Gluconate and Calcium Phospholactate in Combined Dosage Form. Ann Chromatogr Sep Tech. 2017; 3(1): 1028.

Introduction

Calcium is one of the most important nutrients in the human diet, due to its implication in bone health and other physiological functions and enzymatic reactions [1]. Calcium gluconate can be used effectively for treatment of hydrofluoric acid burn [2] and sometimes as a calcium supplement [3]. Solubility of Calcium gluconate makes it appropriate for incorporation into foods [4]. Its empirical formula is C12 H22 CaO14 and its chemical structure is shown in (Figure 1).

Figure 1: Chemical structure of investigated compounds.

Phosphorus is essential for life and plays multiple roles that sustain cellular vitality and as a key structural component of DNA and RNA–sugar phosphates forming the helical structure of every molecule. It is also critical to ATP (adenosine-5’-triphosphate),phospholipids and cell membranes as well as the formation and maintenance of bones and teeth in all vertebrates [5]. Calcium phospholactate (calcium lactophosphate) have been used in drug formulations since 1869 [6]. It’s used as a calcium and/or phosphorus dietary supplement [3]. Its empirical formula is C3 H5 CaO6 P and its chemical structure is shown in (Figure 1).

To the best of my knowledge, no stability indicating HPLC method has been reported yet for simultaneous estimation of calcium gluconate and calcium phospholactate in a combined formula, they are often determined as calcium or phosphorous.Several methods were reported for determination of calcium and/or phosphorous in pharmaceutical dosage forms such as derivative spectrophotometry [7] and potentiometric titration [8].The most widely used technique is atomic absorption spectrometry [9-12] and these methods can’t be used as stability indicating methods because they depend on determination of calcium or phosphorous content not the whole molecule. In this paper the first RP-HPLC method for the simultaneous determination of the mixture of calcium gluconate and calcium phospholactate in tablet dosage form is reported.The method was able to separate each component as well as other unknown degradation products within a run time of 5 minutes.The study was performed in accordance with established ICH guidelines [13] and was successfully applied for simultaneous determination of the combined formula of these two components.

Experimental Section

Chemicals and reagents

HPLC-grade methanol and phosphoric acid were manufactured by Fischer Scientific, UK and purchased from their local agent. Standard materials used were working standard available at our laboratories.The tested formula was a new product developed for registration.

Preparation of Mobile Phase

10 mL of phosphoric acid was added to 950 mL of purified water, then completing the volume to 1000 mL using purified water giving a concentration of 1% (v/v) phosphoric acid. Mobile phase composed of a filtered and degassed mixture of 1% (v/v) phosphoric acid and methanol by (90:10,v/v) ratio.

Chromatographic system

The analysis was performed on a Shimadzu Nexera LC-30AD system (Shimadzu Corporation, Kyoto, Japan) consisting of LC-30 AD-LPGE pump, SPD-20A UV detector and DGU-20A5 Degasser. A Shimadzu SIL-30AC autosampler was used to inject 10 µL of the samples on an Inertsil C18-3 column (4.6 mmx150 mm, 5µm),GL Sciences, Japan), isothermally at 40°C. The detection was carried out at 210 nm. Mobile phase was filtered through a 0.22 µm membrane filter (Chromatech, K or equivalent), then degassed ultrasonically for 5 min and delivered at a flow rate of 1.0 mL/min.

Solutions preparation

Standard solution: Standard solution was prepared by dissolving standard substances in water, then warming gently till complete dissolving, sonicated for 5 min and diluted up to the mark with water to obtain a solution containing, 2.4 mg/mL of calcium gluconate and 2.5 mg/mL of calcium phospholactate.

Sample solution: Twenty tablets were grinded to fine powder. An accurately weighed portion of the powder equivalent to 24 mg of calcium gluconate and 25 mg of calcium phospholactate per tablet were taken in 10 ml volumetric flask. About 5 ml of water was added to this flask and the flask was warmed gently then sonicated in an ultrasonic bath. The volume was completed to the mark using water then filtered through a 0.22 μm syringe filter.

Results and Discussion

Method development and optimization

The main target of the chromatographic method was achieving a method for simultaneous assay for calcium gluconate and calcium phospholactate. The combined standard solution (2.4 mg/mL of calcium gluconate and 2.5 mg/mL of calcium phospholactate) was injected. For method optimization, different chromatographic conditions were experimented to achieve better efficiency of the system. After many trials the method was applied using an Inertsil C18-3 column (4.6 mmx150 mm,5µm) as a stationary phase and mobile phase consisting of 1% (v/v) phosphoric acid and methanol by ratio (90:10,v/v) giving good separation, acceptable retention time, peak shape, plate’s count and good resolution. Chromatogram obtained for the combination upon using final conditions is shown in (Figure 2). Stability indicating capability was established by forced degradation experiments.

Figure 2: Chromatogram of gluconate and phospholactate by proposed method.

Method validation

System suitability: Numerous approaches may be used to set the limits for system suitability tests. This depends on experience with the method, material available and personal preference [14]. System suitability was performed on six replicate injections of mixed standard solution. The relative standard deviation (%RSD) values, tailing factor and number of theoretical plates were the chromatographic parameters selected for the system suitability test. The following requirements were fulfilled, %RSD of peak responses due to each component for the six replicate injections must be less than or equal to 1.0%, tailing factor must be less than 2.0%, resolution must be more than 2 and theoretical plates count must be more than 2000. System suitability parameters were calculated and are presented in Table 1.

Table 1: System suitability parameters.

  Parameter Calcium Calcium
No. gluconate phospholactate
1 Retention time 1.736 2.675
2 USP resolution -- 7.087
3 Tailing factor 1.29 1.148
4 No. of theoretical plates 3019 5969
5 Area [RSD (%), n=6] 0.184 0.178

Linearity: In chromatography, peak parameters are related to analyte concentration via standardization procedures. This relationship is then used to convert a sample’s peak parameter to its apparent analyte concentration. A linearity assessment establishes the nature of the peak parameter relative to analyte concentration. The linearity assessment determines the procedure’s ability to obtain test results which are proportional to the concentration of the analyte in the sample within a given range either directly or via a well-defined mathematical transformation [15]. It was studied by preparing standard solution of five concentration levels ranging from 80 % to 120 % of test concentration (1.92-2.88 mg/mL of calcium gluconate and 2-3 mg/mL of calcium phospholactate) and analyzed in triplicate per level (Figure 3).

Figure 3: Overlay linearity Chromatogram (80–120%) for calcium gluconate (1) and calcium phospholactate (2).

The graphs were plotted using peak responses of each component on Y-axis and the corresponding concentration on X-axis. The peak area ratios of calcium gluconate and calcium phospholactate were linear with respect to the concentrations of the two analytes. A good correlation was found between the observed peak area ratios (y) and the theoretical concentration (x). Least squares regression analysis provided typical regression lines: y=166.6x–13194 (r2=0.9982) for calcium gluconate and y=162.3x–16567 (r2=0.9981) for calcium phospholactate.

Precision: Precision is the measure of the degree of repeatability of an analytical method under normal operation and is normally expressed as the percent relative standard deviation (%RSD) for a statistically significant number of samples [16]. The precision of the method was established by carrying out the analysis of 100% concentration of the analyte for six times. The obtained low value of standard deviation showed that the method is precise. The results obtained are presented in Table 2.

Table 2: Method precision results.

No. Calcium gluconate Calcium phospholactate
  377098 379743
  377134 378561
  376269 378421
  376027 378568
  375774 378186
  375353 377769
Mean 376275.8 378541.3
SD 718.03 660.66
RSD% 0.191 0.175

Accuracy: Accuracy is the degree of agreement between the experimental value, obtained by replicate measurements, and the accepted reference value. It has been pointed out that the accuracy is the most crucial aspect that any analytical method should address [17]. The accuracy of the method was verified by adding different amounts of known standards to the sample solution then determining the percentage recovery of each concentration with respect to real values. The accuracy of the assay method was evaluated in triplicate at three concentration levels 80%,100% and 120% of the label claim. Amount of drug recovered was quantified and % recovery was calculated. The results of the accuracy study are reported in Table 3. For the two drugs, at the different concentration levels, good recoveries were obtained meeting the acceptance criteria of 100±2%. These results reveal the good accuracy of the proposed methods and providing the working range for the method.

Table 3: Results of the Accuracy study.

Component Spiked level (%, Spiked conc. (µg/ Recovery
n=3) ml) (%)
  80 1920 100.59
  100 2400 100.79
Calcium gluconate 120 2880 99.71
  80 2000 100.5
Calcium phospholactate 100 2500 99.85
  120 3000 100.75

Specificity: Specificity is the ability of the method to measure the analyte response in the presence of its potential impurities [18]. Forced degradation studies were performed to demonstrate selectivity of the method using 0.1M HCl,0.1M NaOH and thermal (80°C). The degradation samples were prepared by taking suitable aliquots of the drug solution, and then undertaking the respective stress testing procedures for each solution. After the fixed time period the treated drug solutions were diluted with water. For every stress condition drug solution was prepared as 2400 μg/ml of calcium gluconate and 2500 μg/ml of calcium phospholactate. The specific stress conditions are described as follows. Acidic degradation was carried out by adding 1.0 mL of 0.1M HCl, and after 30 min neutralizing the mixture by adding 0.1M NaOH. Alkali degradation was carried out by adding 1.0 mL of 0.1M NaOH, and after 30 min neutralizing the mixture by adding 0.1M HCl. Thermal degradation was performed by heating the drug solutions at 80°C on a water bath for 45min.

After the degradation process, samples were allowed to cool at room temperature and diluted, if necessary, to the same concentration as that of the standard solution, after being neutralized. Calcium gluconate and calcium phospholactate were found to be sensitive to acid, base and thermal degradation (Figure:4a-d).

Figure 4a: Acid degradation chromatogram.

Figure 4b: Base degradation chromatogram.

Figure 4c: Thermal degradation chromatogram.

Figure 4d: Placebo chromatogram.

The figures show that there is no interference at the retention time of calcium gluconate and calcium phospholactate due to placebo or degradation products, indicating that the method is selective.

Robustness: Robustness of the developed method was determined by analyzing the samples after some small but deliberate changes in the method parameters such as change in flow rate (±0.2 mL/min), change in organic composition of mobile phase by (±5%). Changes in chromatographic parameters such as theoretical plates count and tailing factor were evaluated for the studies and are shown in Table 4. The method is robust for all tested parameters.

Table 4: Robustness evaluation of the method.

Chromatographic

changes

%RSD (Peak Area)

n = 6

Tailing

factor

Theoretical plate

count

Calcium gluconate

 

Flow rate (mL/min)

0.8

0.15

1.33

3489

1.0

0.16

1.30

2993

1.2

0.18

1.35

2989

Organic composition

(%)

 

5

0.24

1.36

2841

10

0.15

1.31

3135

15

0.17

1.29

2933

Calcium

phospholactate

 

Flow rate (mL/min)

0.8

0.11

1.17

7393

1.0

0.13

1.16

5888

1.2

0.12

1.14

6931

Organic composition

(%)

 

5

0.13

1.16

6595

10

0.12

1.16

5909

15

0.14

1.13

6399

Limit of Detection (LOD) and Limit of Quantitation (LOQ): Sensitivity of the method was proved by establishing the Limits of Detection (LOD) and Quantitation (LOQ) for calcium gluconate and calcium phospholactate in pure and in dosage forms. The LOD and LOQ were determined by visual inspection using signal to noise approach, by injecting a series of dilute solutions with known concentrations. The concentration (in μg/mL) with signal to noise ratio of at least 3 was taken as LOD and concentration with signal to noise ratio of at least 10 was taken as LOQ. The limit of detection of calcium gluconate and calcium phospholactate was 32.7 and 27.6 μg/mL, respectively. The limit of quantification was 96.6 and 78.4 μg/mL,respectively.

Stability of standard solution, sample solution and mobile phase: The solution stability was checked by leaving the both the solutions of sample and standard in tightly capped volumetric flasks at room temperature for 2 days. The same sample solutions were analyzed after 2 days. The mobile phase stability was also carried out by assaying the freshly prepared sample solutions against freshly prepared standard solution for 2 days. Mobile phase was kept constant during the study period. There is no significant change in the solutions up to a period of 2 days; all the drugs had enough stability up to 2 days after preparation.

Conclusion

A novel stability indicating RP-HPLC method was successfully developed and validated for simultaneous determination calcium gluconate and calcium phospholactate in tablets dosage form. All the drugs were found to be well resolved in a run time of 5 min. No interference was found with the degradants and excipients. Validation results have proved that the method is selective, precise, accurate, robust and stability indicating which can be successfully applied for the routine analysis as well as for stability studies.

Acknowledgement

The author is grateful to the management of Unipharma Company for encouraging such work.

References

1. Ribeiro ACF, Rita MBBJ, Gomes JCS, Lobo VMM, Esteso MA. Diffusion of calcium gluconate in aqueous solutions of lactose at 298.15 K. Food Chemistry. 2011; 126: 1186-1189.

2. Zhang Y, Wang X, Ye C, Liu L, Jiang R, Ni L, et al. The clinical effectiveness of the intravenous infusion of calcium gluconate for treatment of hydrofluoric acid burn of distal limbs. Burns. 2014; 40: e26-e30.

3. Medilexicon.

4. Korstanje R, Hoek M. Calcium and other minerals, In Young J (editor), Guide to functional foods ingredients. LFRA Ltd. England. 2001; 197-210.

5. Childers DL, Corman J, Edwards M, Elser JJ. Sustainability Challenges of Phosphorus and Food: Solutions from Closing the Human Phosphorus Cycle. BioScience. 2011; 61: 117-124.

6. Husa WJ, McLean AP. History of the Calcium Lactophosphate Preparations. The Journal of the American Pharmaceutical Association (1912).1935; 24: 58-60.

7. Benamor M, Aguerssif N. Simultaneous determination of calcium and magnesium by derivative spectrophotometry in pharmaceutical products. Spectrochimica Acta Part A. 2008, 69: 676-681.

8. Ramadoss K, Murty DSR, Mahanta PL, Gomathy B, Rangaswamy R. Determination of phosphorous in titanium bearing minerals by potentiometric titration using Pb-ion selective electrode. Talanta. 2000; 51: 57-62.

9. Udoh AP. Atomic absorption spectrometric determination of calcium and other metallic elements in some animal protein sources. Talanta. 2000; 52: 749-754.

10. Udoh AP. Determination of calcium, magnesium and zinc in unused lubricating oils by atomic absorption spectroscopy. Talanta. 1995; 42: 1827-1831. 

11. Lopez-Garcia I, Vinas P, Romero-RomeroR, Hernandez-CordobaM. Fast determination of phosphorus in honey, milk and infant formulas by electrothermal atomic absorption spectrometry using a slurry sampling procedure.Spectrochimica Acta Part B. 2007; 62: 48-55.

12. Resano M, Briceno J, Belarra MA. Direct determination of phosphorus in biological samples using a solid sampling-high resolution-continuum source electrothermal spectrometer: comparison of atomic and molecular absorption spectrometry. Journal of Analytical Atomic Spectrometry. 2009; 24: 1343 1354.

13. International Conference on Harmonization (ICH) Q1A (R2): Stability Testing of New Drug Substances and Products, USA: ICH. 2003.

14. Chandran S, Singh R S P. Comparison of various international guidelines for analytical method validation. Pharmazie. 2007; 62: 4-14.

15. Jenke DR. Chromatographic method validation: a review of current practices and procedures. ii. Guidelines for primary validation parameters. Journal of Liquid Chromatography & Related Technologies. 1996; 19: 737-757.

16. SwartzME, KrullIS. Analytical method development and validation, Marcel Dekker Inc., New York. 1997.

17. Araujo P. Key aspects of analytical method validation and linearity evaluation. Journal of Chromatography B. 2009; 877: 2224-2234.

18. International Conference on Harmonization (ICH) Q2 (R1): Validation of Analytical Procedures-Test and Methodology, Geneva, Switzerland: ICH; 2005.

Other Articles

Article Image 1

Removal of Acid Beverage Flocs in Crystal Sugar by Adsorption Column Chromatography: Preliminary Study with Adsorbent Resin

The sugar industry has been facing some problems with white sugar intended for soft drinks production. Some studies have been demonstrated the sugar could be source of insoluble substances technically called by Acid Beverage Flocs (ABF). It appears during the beverage production; however, the flocs are easily disappearing with shaking. This may be related to raw material the sugarcane quality and, consequently, with the efficiency of the juice clarification process, since if there is no adequate juice treatment. The sugarcane commonly has lower quality and higher intensity of impurities, such as proteins, wax, minerals and colloids. The sugar industries are implementing solutions to reduce the amount of impurities through using technologies like ionic resins to removal of color, odor or undesirable taste. It could transform raw sugar in refined or white sugars. The aim of this work was evaluate the efficiency of purification of sugar solution with chromatographic adsorption system. We observed that the color reduction was around 69% and an intensive reduction in turbidity of sugar aqueous solution. There were variation on sucrose and increase on reducing sugars (glucose and fructose) contents. It is possible to conclude that the process could be efficient to reduce the color (MAU color), turbidity and ABF into sugar solutions.

Roberta Bergamin Lima and Claudio Lima de Aguiar*


Article Image 1

A Study to Evaluate Aflatoxin Contamination in Food from Gauteng Province

Aflatoxins (AFs) and their producers have been found to be problematic and is still an issue. This is due to their role in influencing food quality, health and economy loss. In maintaining good food quality, minimize AFs occurrence and its deleterious effects, it is essential that issues relating to mycotoxin production and contamination are monitored, and addressed on a regular basis. This will proffer suggestions for immediate actions to be taken, in order to achieve and maintain regulatory limit before situations are out of control. Hence the case study to evaluate the concentration of AFs in food, by way of thin layer chromatography and high performance liquid chromatography was attempted. This is to monitor concentrations of the emerging mycotoxin in relation to international regulatory limits. Concentrations levels ranging 0.06 - 77.97 ppb was observed, (mean: 16.8 ppb) and measured out in the food samples of study, exceeding the ISO limits (0.05 ppb). This calls for proper monitoring of pre and postproduction stages in food, by employing easy to use chromatographic techniques as a routine process to screen and ascertain concentrations do not exceed regulatory limits.

Henry E Iheanacho¹,²,³*


Article Image 1

Investigation of Naturally Occurring Fumonisin B1 and Glycated Fumonisin B1 in Korean Feedstuffs

Mycotoxins are potentially dangerous contaminants of livestock feeds. In this study, we measured the levels of fumonisin B1 and glycated fumonisin B1 in feedstuffs and then investigated the ability of the extrusion heating regimen to convert the most prevalent mycotoxin contaminant, fumonisin B1 , to a less toxic glycated form. All feed samples were analyzed with fully validated methods. All measured concentrations of fumonisin B1 were below harmful thresholds, including European Union-recommended levels or US Food and Drug Administration action levels.

Because fumonisin B1 was highly contaminated mycotoxin in our present investigation and fumonisin B1 has been shown to be less toxic following Maillard type reaction with reducing sugar, we examined the formation of fumonisin B1 derivatives by Maillard reaction under extrusion process conditions. We employed a variety of tandem mass spectrometric methodologies to selectively detect fumonisin B1 derivatives and to elucidate their structures partially. We found that compounds of m/z 736 were more likely artifacts or side reaction products rather than glycation products. N-(carboxymethyl) fumonisin B1 of m/z 780 and other major glycation products of m/z 794 and 810 were not detected, and only negligible amounts of methylene fumonisin B1 was found in 10 extruded feed samples. Therefore, either the tested extrusion conditions did not induce fumonisin B1 glycation or the glycation products simply could not be detected by the method employed in this study.

Jongsung Ahn¹, Hyenjong Kim¹, and Kwang-Yeop Jahng²*


Article Image 1

Determination of HMF in Some Instant Foods and Its Biodegradation by Some Lactic Acid Bacteria in Medium and Food

The aims of this study were to determine HMF level in some foods and to reduce their level by biodegradation. Coffee whitener, cappuccino, hot chocolate, instant coffee, instant powdered mix (coffee, coffee whitener and sugar) and aromatized cocoa were subjected to HMF analysis in the scope of this study. The HMF determination of samples was carried out using a high performance liquid chromatography. Color properties of the samples were determined according to standard procedures and their relations with HMF content were also investigated. The biological degradation of HMF with lactic acid bacteria was also studied with broth media and a model food system (reconstituted milk).The average HMF levels were 12.59 mg/kg for coffee whitener, 572.49 mg/ kg for cappuccino, 660.29 mg/kg for hot chocolate, 1804.91 mg/kg for instant coffee, 871.56 mg/kg for instant powdered mix and 980.94 mg/kg for aromatized cocoa. The addition of lactic acid cultures reduced the HMF content of the samples. HMF levels of broth media and model food inoculated with lactic acid bacteria (L. lactis, L.bulgaricus, L. cremoris) decreased about 25 % as a result of HMF biodegradation.

Rasim Alper Oral¹, Mahmut Dogan², Kemal Sarıoglu², Ahmed Kayacıer¹, and Osman Sagdic³*


Article Image 1

An Integrated Analysis of the Musa Paradisiaca Peel, Using UHPLC-ESI, FT IR and Confocal Microscopy Techniques

When the banana (Musa paradisiaca) peel was subject of enzymatic hydrolysis with cellulase and hemicellulase, only glucose was obtained. Images from banana peel, using confocal laser scanning microscopy, demonstrate that the cellulose is the main structural compound. Fatty acids, phenolic and other compounds were detected from the organic residual extract, and characterized by means of NMR, FT-IR and UHPLC-MS techniques. The presences of these compounds were corroborated through a steam distillation. Under this condition, banana peel could have potential applications in the food field, where could be used to improve some procedures such as the obtaining of banana vinegar.

Miriam Alejandra González Corona¹, Mayra Beatriz Gómez-Patiño², María de Jesús Perea Flores², Luis Alberto Moreno Ruiz², Blanca Margarita Berdeja Martinez¹, and Daniel Arrieta-Baez²*


Article Image 1

Structural Characterization of Bamboo Lignin Isolated With Formic Acid and Alkaline Peroxide by Gel Permeation Chromatography and Pyrolysis Gas Chromatography Mass Spectrometry

Fractionation is an effective technology to maximize the utilization of lignocelluloses for the production of chemicals and materials. In this case, bamboo was subjected to a two-step fractionation process based on the concept of biorefinery: (a) formic acid treatment at boiling point under atmospheric pressure for 2 h, and (b) post treatment with alkaline hydrogen peroxide solution containing 1% NaOH and 1% H2 O2 at 80 ºC. The combination of formic acid delignification and alkaline hydrogen peroxide degradation achieved an effective removal of both lignin (delignification rate 94.9%) and hemicelluloses (removal rate 87.4%) from bamboo, producing cellulose rich pulp, formic acid lignin and sugars. To investigate the structural modification of lignin during the fractionation process, the residual lignin in the treated samples was isolated and characterized with multiply techniques including gel permeation chromatography, pyrolysis gas chromatography mass spectrometry, Fourier-transform infrared spectroscopy, etc. The relative ratio of S/G was 1.63 for bamboo milled wood lignin (L1), whereas the lignin isolated from the formic acid treated cellulose-rich fraction (L2) presented a chromatograph similar to that of L1 but had a lower S/G ratio of 1.28. This indicated that a preferential removal of S units during the formic acid fractionation process. In addition, alkaline hydrogen peroxide treatment resulted in more removal of S units, as indicated by a lower S/G ratio of 0.71.

Xun Li¹, Chang-Zhou Chen¹, and Ming-Fei Li¹*

 


Article Image 1

Volatile Compound Profiles by HS GC MS for the Evaluation of Postharvest Conditions of a Peach Cultivar

Volatile Organic Compounds (VOCs) profile of foods obtained by Gas Chromatography/Mass Spectrometry (GC/MS) can be considered a potent tool of food products quality changes occurring as a result of different processing, such as ripening and deterioration. The aim of the present study was the evaluation of volatiles profiles of peaches (cv Springcrest) during their storage in conditions similar to those of long distance transport that normally these products undergo before being placed on market. We investigated control sample (no stored fruit) and peaches stored in cardboard boxes wrapped in heat-sealed HD polythene bags, both in normal and modified atmosphere (0% and 23% CO2 ) after 1 and 8 days of storage at 4°C. GC/MS analysis of these samples allowed the identification of a total of 115 VOCs.

The comparison of the VOCs profile of the three peach samples (control, normal atmosphere and 23% CO2 ) shows that fruits packaged in normal atmosphere released a greater amount of esters of medium chain fatty acids, such as ethyl nonanoate and ethyl dodecanoate. On the other hand, fruits stored in normal atmosphere and modified atmosphere after 8 days of storage (increased concentration of CO2 in packs) released a greater amount of esters of long chain fatty acids, such as ethyl hexadecanoate.

Livia Malorni¹, Antonella Martignetti¹, and Rosaria Cozzolino¹*


Article Image 1

Current Trends in Lignocellulosic Analysis with Chromatography

The conversion of lignocellulosic biomass into biofuel and biomaterial is promising for the substitution of fossil resources in energy and material applications. Given the complexity of plant cell wall, the main challenge is to obtain lignocelluloses with high yield and purity. For a better understanding of lignocellulosic biomass, chromatography stands out as a powerful separation method that can support the lab directed research and pilot scale production of biomaterial and biochemical. This paper provides a review on the characterization of cellulose, hemicellulose and lignin along with their derivatives and decomposed sugar monomers, in particular their isolation and purificationmethods using various specific types of chromatography. Methods with various specific types of chromatography. This review also summarizes different chromatographic methods for obtaining the molecular weights of cellulose, hemicellulose and lignin that have been used in recent years, and highlights future opportunities for the application of those biopolymers.

Fengbo Sun¹ and Qining Sun²*


Article Image 1

Current Status of Two-Dimensional Gel Electrophoresis and Multi-Dimensional Liquid Chromatography as Proteomic Separation Techniques

Proteomics is very important component in the era of post-genomics because it can address functions of genes and some important non-gene-determined biological issues such as Post Translational Modifications (PTMs), splicing, translocation, and spatial structure. Proteome is very complex, including multiple parameters such as kind of proteins, copy number of each protein, PTMs, isoforms, spatial structure of each protein, protein-protein interaction, and protein-other molecule interaction, etc. Moreover, proteome is dynamic, and alters with different conditions such as different physiological processes, different pathological processes, and different disease status.

Xianquan Zhan¹,²,³,⁴*


Article Image 1

Validation of Assay Indicating Method Development of Imatinib in Bulk and Its Capsule Dosage Form by Liquid Chromatography

A novel, simple and economic reverse phase High Performance Liquid Chromatography (RP-HPLC) method has been developed for the quantification of Imatinib in bulk and capsule dosage form with greater precision and accuracy. Separation was achieved on Analytical technologies, C-18, (250mm*4.6mm) column in isocratic mode with mobile phase consisting of acetonitrile: potassium dihydrogen phosphate buffer (pH 2.5) (30:70v/v) with a f low rate of 0.8 mL/min. The detection was carried out at 268 nm. The retention time of Imatinib was found to be 2.67 min. The method was validated as per ICH guidelines. Linearity was established for Imatinib in the range 5-35 μg / ml with r2 value 0.996. The percentage recovery of Imatinib was found to be in the range 99.49-99.67 %. The high recovery and low relative standard deviation confirm the suitability of the proposed method for the estimation of the drug in bulk and capsule dosage forms. Validation studies demonstrated that the proposed RP-HPLC method is simple, specific, rapid, reliable and reproducible for the determination of Imatinib for quality control level.

Nalini Kanta Sahoo¹, Madhusmita Sahu¹, V Alagarsamy¹, B Srividya², and Chinmaya Keshari Sahoo³*